电脑桌面
添加文秘网到电脑桌面
安装后可以在桌面快捷访问

水喷雾灭火系统在液化烃储罐消防的应用(张学军)

栏目:农林鱼水论文发布:2010-03-12浏览:2566下载154次收藏
  #trs_autoadd_1231035892937 { margin-top: 0px; font-size: 12pt; margin-bottom: 0px; line-height: 1.5; font-family: 宋体 } #trs_autoadd_1231035892937 p { margin-top: 0px; font-size: 12pt; margin-bottom: 0px; line-height: 1.5; font-family: 宋体 } #trs_autoadd_1231035892937 td { margin-top: 0px; font-size: 12pt; margin-bottom: 0px; line-height: 1.5; font-family: 宋体 } #trs_autoadd_1231035892937 div { margin-top: 0px; font-size: 12pt; margin-bottom: 0px; line-height: 1.5; font-family: 宋体 } #trs_autoadd_1231035892937 li { margin-top: 0px; font-size: 12pt; margin-bottom: 0px; line-height: 1.5; font-family: 宋体 } /**---json-- {"":{"line-height":"1.5","font-family":"宋体","font-size":"12pt","margin-top":"0","margin-bottom":"0"},"p":{"line-height":"1.5","font-family":"宋体","font-size":"12pt","margin-top":"0","margin-bottom":"0"},"td":{"line-height":"1.5","font-family":"宋体","font-size":"12pt","margin-top":"0","margin-bottom":"0"},"div":{"line-height":"1.5","font-family":"宋体","font-size":"12pt","margin-top":"0","margin-bottom":"0"},"li":{"line-height":"1.5","font-family":"宋体","font-size":"12pt","margin-top":"0","margin-bottom":"0"}} --**/

我国引进的大型石油化工装置的液化烃储罐均设置了水喷雾灭火系统,设计规范多采用美国《nfpa-15》标准和日本《液化石油气设计防火设备规程》。遵循引进吸收国产化的原则,执行《石油化工企业设计防火规范》(gb50160-92)[1](1999年版),在扬子石化公司炼油厂催化裂化装置的液化烃储罐消防设计中选用了水喷雾灭火系统,并获得上级消防部门的批准确认。

 

1 水消防系统选择

 

1.1 喷淋冷却和消防喷淋分别设置系统

 

催化裂化装置液化烃罐区共有2个1 000m3 容积的液化泾球罐。球罐直径12.3m,外壁无保温设施。

 

液化烃类闪点小于28℃,火灾危险性属于甲a类。其储罐多为球罐,罐内压力较高,一旦发生火灾则很难扑救,甚至发生爆炸,引发火灾蔓延,造成连锁性事故。根据有关资料介绍,地上式钢制储罐发生火灾,5 min内可使罐壁温度升至500 ℃,使钢板强度降低一半。储罐发生火灾,为控制火势,降低火焰辐射强度,必须对储罐及时进行水喷淋冷却,使罐壁温升不超过100℃。附着罐壁 的水膜,没有充分受热完全气化,则罐壁不会形成过热,罐的

解锁后支持完整在线阅读或下载编辑海量优质内容资源

水喷雾灭火系统在液化烃储罐消防的应用(张学军)

点击下载
分享:
热门文章
    热门标签
    确认删除?
    QQ
    • QQ点击这里给我发消息
    回到顶部