{"":{"line-height":"1.5","font-family":"宋体","font-size":"12pt","margin-top":"0","margin-bottom":"0"},"p":{"line-height":"1.5","font-family":"宋体","font-size":"12pt","margin-top":"0","margin-bottom":"0"},"td":{"line-height":"1.5","font-family":"宋体","font-size":"12pt","margin-top":"0","margin-bottom":"0"},"div":{"line-height":"1.5","font-family":"宋体","font-size":"12pt","margin-top":"0","margin-bottom":"0"},"li":{"line-height":"1.5","font-family":"宋体","font-size":"12pt","margin-top":"0","margin-bottom":"0"}}
--**/
摘 要: 泵组超负荷运转是泵站生产中经常遇见的现象,本文结合实例进行了原因分析,并提出了解决方案,应用效果良好,值得推广。
关键词:泵组 超负荷运转 过流 叶轮 切削
1 问题的提出
獭湖泵站系深圳市东部供水水源工程调蓄泵站,按综合自动化系统模式进行设计和配置,装机6×280kw,四用二备,设计流量约1.5m3/s,设计扬程12.5m,调蓄水库设计蓄水水位为66m。受深圳市长期缺水局面影响,调蓄水库蓄水水位从未达到设计水位66m,日常运行基本保持在59m以下,泵组基本以2台运行甚至单台运行。为测试调蓄水库大坝高水位运行下的渗漏情况,需要开展水库调蓄工作,将蓄水水位逐级提高,相应泵组数量逐
泵组超负荷运转原因分析及解决方案(彭琳)
点击下载
本文2010-03-12 15:16:48发表“农林鱼水论文”栏目。
本文链接:https://www.wenmi123.com/article/152503.html
您需要登录后才可以发表评论, 登录 或者 注册