{"":{"line-height":"1.5","font-family":"宋体","font-size":"12pt","margin-top":"0","margin-bottom":"0"},"p":{"line-height":"1.5","font-family":"宋体","font-size":"12pt","margin-top":"0","margin-bottom":"0"},"td":{"line-height":"1.5","font-family":"宋体","font-size":"12pt","margin-top":"0","margin-bottom":"0"},"div":{"line-height":"1.5","font-family":"宋体","font-size":"12pt","margin-top":"0","margin-bottom":"0"},"li":{"line-height":"1.5","font-family":"宋体","font-size":"12pt","margin-top":"0","margin-bottom":"0"}}
--**/
1 前 言
独山子热电厂有三台发电机组,分别为25mw、25mw、50mw,合计发电量为100mw。有三台双曲线自然通风式冷却塔,总循环水量为10 300m3/h,保有水量为11 000 m3。自投产以来,一直未做处理,同时与鱼池相连,存在着较为严重的腐蚀问题和生物粘泥问题,每年因腐蚀问题造成凝汽器铜管泄漏达200根,由于生物粘泥,每个季度都需要胶球清洗,有时需要高压水冲击,造成检修费用大大增加。因为冷却不下来,各用水部门在天热时加生水冷却,造成用水量增加。针对这些问题,我们做了全面调研,采取切断鱼池